No. Colour and static coil resistance are not sufficient interchange criteria. Two solenoids can pass a basic electrical resistance check yet differ in hydraulic duty, flow/pressure response, connector, control strategy or manufacturer-defined calibration. Identical paint markings can also be a misleading purchasing shortcut.
Match the gearbox and solenoid position, original part/assembly identifier, manufacturer-approved replacement and any calibration requirements. For functional assessment, distinguish an electrical check from an actual response test: energising a coil does not establish that the hydraulic output meets the intended specification.
See the SUPER5 solenoid compatibility guide and the first-party 8HP70 valve-body hydraulic-testing record for that distinction.